Ada instruments prolevel 403/11/2023 Remove the battery when not in use for an extended period of time.įailure to follow the instructions listed below may cause personal injury.Check the battery regularity, avoid deterioration.Do not operate the tool in the water and dust, avoid to damage the tool.Don’t place the product with corrosive any gas or objects.Don’t disassemble the product to avoid failure.Don’t drop the product or use by force.The best way to recognize the right wood moisture content is to measure continuously day after day to obtain the corresponding values and compare to judge. Wood moisture values are related to ambient temperature humidity and wood material density.Please replace the battery when the unit cannot be powered on or low battery indicator is on.The product has external calibration function Remove the protection cap, power on the unit, place the 2 pins into the 2 holes at the back of the cover, just now the LCD shows a value between 18.2%☐.3% If beyond this range, the accuracy has problem, advise to be repaired. When it is lower than 1.5%, the screen shows” _ _ _”, when it is higher than 33%, the screen shows “ _ _ _ ”.Ħ) Press the Hold button I during measuring, the symbol “HOLD” will display and hold the data, press again to make “HOLD” disappear and exit data hold.ħ) Keeping pressing the Hold button to turn off the buzzer sound during measuring.Ĩ) Keeping pressing the power button for 2s to turn off the product. Withiut limiting the foregoing, leakage of the battery, bending or dropping the unit are presumed to be defects resulting from misuse or abuse.The screen shows” _ _ _”, when it is higher than 50%, the screen shows “ _ _ _ ”.ĥ) Under building material mode, reading of the target material is displayed on LCD screen, available range is 1.5%~33%. The warranty will not apply to this product if it has been misused, abused or altered. In case of a defect please contact the dealer where you originally purchased this product. This product is warranted by the manufacturer to the original purchaser to be free from defects in material and workmanship under normal use for a period of two (2) years from the date of purchase.ĭuring the warranty period, and upon proof of purchase, the product will be repaired or replaced (with the same or similar model at manufactures option), without charge for either parts of labour. If the sound mode has been activated, the level will beep at 0.0%. When the conversion button is in the slope mode, it will display (%). This is useful when laying pipe for proper drainage. The digital level measures the slope of a surface in percent. ![]() The sound function utilizes a series of beeps that increase in tempo eventually reaching a constant tone at exactly 0 and 90 degrees as it approaches 0 and 90 degreees. Beeper will sound at level (0) and plumb (90). Press and hold button for 3 seconds to activate sound function. An auto-off feature shuts the display off after a period of inactivity to preserve battery life.Ģ) Button B - press once to enter the HOLD function and for the H iconīe displayed, press once again to release hold function. Press the button again to set current angle to zero, REF icon will be displayed to indicate relative angle measurement mode. Indicates that the digital level is calibrating for another direction.ġ) Button A - press once to turn the LCD display on. Indicates that the digital level is calibrating for one direction. This icon appears on the screen when the HOLD function is activated. ![]() Indicates that the level is working in relative angle mode. Sound/Beeper Icon - this icon appears on the screen when the beeper function is activated. Only displayed when battery power is low. Replace batteries when the Battery Power Icon is displayed.
0 Comments
Leave a Reply.AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |